Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Reference: RBD-2072
Operating Voltage: 3.3V-5V Features wide range voltage comparator LM393 Adjustable sensitivity Signal output indicator with the retaining bolt hole, convenient installation Output form digital switch output (0 and 1 high and low level) The output effective signal is low level When there is sound, outputs low level and the signal light
Reference: RBD-2967
Introducing the latest addition to RoboticsBD's product lineup, the 0.2MPa Stainless Steel Pressure Transducer Sensor. Crafted with high-quality stainless steel, this pressure transducer offers exceptional rigidity and durability, making it ideal for a variety of applications.
Reference: RBD-2073
Digital Output Hall-effect sensor. Operating voltage: typically 5V. Output Current: 25mA. It can be used to detect both the poles of a magnet.
Reference: RBD-2968
Introducing the latest addition to RoboticsBD's product lineup, the 10MPa Stainless Steel Pressure Transducer Sensor. Crafted with high-quality stainless steel, this pressure transducer offers exceptional rigidity and durability, making it ideal for a variety of applications.
Reference: RBD-2120
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA.
Reference: RBD-2978
Flow Range:0.3 to 6L Input/Output Diameter: 6.5mm Minimum rated working voltage: DC 5~24V Max. working current: 15mA (DC 5V) Working voltage range: DC 5~24V Load capability: <= 10mA (DC 5V)
Reference: RBD-0311
Working Voltage: 5 to 18V DC (min tested working voltage 4.5V). RoboticsBD Max current draw: 15mA @ 5V. Working Flow Rate: 1 to 30 Liters/Minute. Maximum water pressure: 2.0 MPa. Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min). RoboticsBD
Reference: RBD-2224
Voltage – 250V Easy PCB mounting Good consistency Widely acclaimed
Reference: RBD-2342
INA3221 Triple-Channel Shunt Current and Voltage Monitor Sensor Board Measures high-side current and bus voltage with I2C and SMBUS compatibility Monitors bus voltages (0V to 26V) and shunt voltage drops with high accuracy Programmable alerts, averaging modes, and conversion times for enhanced control Compact design with four programmable I2C addresses...
Reference: RBD-2979
Working voltage: DC1.8-7V(low consumption version),7-24V(regular version), 7-24V(PLC version) Rated voltage: 7 to 24 V Pulse output duty cycle: 50+-10% Insulation resistance: 100M Ohm and above Input/Output Diameter: 9.5mm
Reference: RBD-2980
Working voltage range: DC 5 – 18V. Load capacity: ≤ 10 mA (DC 5V). Working temperature: ≤ 80 ℃ Lightweight, small size, easy to install. Inlaid with stainless steel impeller shaft, durable wearable. The seal ring with the upper and lower force structure never leaks. Non-violent shock, and chemical erosion.
Reference: RBD-2361
Bi-directional Hall-effect current sensor with a ±50A detection range. Accurate and stable current measurement with a 40mV/A linearity. Compact design with easy mounting capability for versatile applications. Wide operating temperature range: -40°C to 150°C, suitable for harsh environments. Based on ACS758LCB-050B IC, offering high reliability and low...
Reference: RBD-2981
Model: YF-S402C Specification: G3/8 Input/output size: 15mm Operating voltage 5 to 18 V Analog Sensor Accuracy Up to 5% Water Proof Sensor
Reference: RBD-2653
2.8V-5.5V to ±12V DC Conversion Step Up Power Supply Module is straightforward. There is a 2.8 to 5.5 V DC input and the module outputs +12 V and -12 V DC dual power supply voltage with a current rating of a maximum 30 mA. Off course the current output is low but sometimes it suits in many situations where one is looking forward for a small boost...
Reference: RBD-2982
Measures water flow from 10 to 200 liters per minute. Hall-effect sensor for accurate pulse signal output. Durable plastic body; waterproof, heat-resistant, and pressure-resistant. Suitable for industrial flow measurement applications. Easy installation and maintenance.
Reference: RBD-2675
You can also use the IICLCD1602 LCD to display voltage. By 3P connector, connect this module with the expansion of board Arduino Voltage input range: DC 0-25 V Voltage detection range: DC 0.02445 V to 25 V Voltage analog resolution : 0.00489 V
Reference: RBD-2983
Measures water flow from 1 to 120 liters per minute. Features a durable ABS and metal construction. Equipped with a hall-effect sensor for accurate pulse signal output. Suitable for use in water dispensers, coffee machines, and irrigation systems. Withstands water pressure up to 2.0 MPa.
Reference: RBD-2677
Operating on a 5V DC power supply with a current consumption of less than 60mA, this 0.28-inch Digital Voltmeter Ammeter is a versatile tool for measuring voltage and current. With a testing range of 0-100V for voltage and 1-100A for current, this meter offers precise measurements with easy readability, even in dim light conditions.
Reference: RBD-2984
Measures water flow rates from 1 to 30 liters per minute. Equipped with a magnetic hall-effect sensor for pulse output. High-quality sealing and durability, suitable for various water line applications. Simple and compact design for easy installation. Requires calibration for precise measurements.
Reference: RBD-2686
Operating current: 20mA Operating voltage: DC 4.5 ~ 30V Minimum resolution(V): 0.1V Minimum resolution(A): 0.01A Display color: Red and Blue (two-color display) Measure accuracy: 1% Dual Led 0.28 ” Display for DC0-100V 100A Voltage and Current Test Digital Instrument, Digital Meter Panel Amplifier Red Blue 100A