Reference: RBD-1354
Jumper Wire Single 20cm
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-1354
Length: 8 inches/20 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0351
Contactless transmission of data and supply energy (no battery needed) Operating distance: Up to 100mm (depending on antenna geometry) RoboticsBD Operating frequency: 13.56MHz Data transfer: 106 kbit/s Data integrity: 16 Bit CRC, parity, bit coding bit counting Anticollision Typical ticketing transaction: <100 ms ( including backup management)...
Reference: 0245
Choose your desire Resistor value from below:
Reference: 0031
3 Types Available (Please select from option) 1. Male to Male 2. Male to Female 3. Female-Female
Reference: RBD-0768
Size: 5mm Color: RED Head Shape: Round Lens Appearance: Transparent
Reference: 1353
Length: 12.5 inches/30 CM (Long) Material: Copper Plated Pin Spacing: 2.54mm.
Reference: RBD-0761
Breadboard friendly Mounting Style: Through Hole Mounting Direction: Vertical
Selecting the most reliable sensor for any Application is quite tricky as you need to think over various specs like its size, accuracy, operating specifications, and most importantly, its price. Here, we carry around 150+ differential sensors with all technical specifications and its application guidelines to narrow down your search filters which gives the highest level of satisfaction to you. Explore a wide range of best-picked sensors by Robotics Bangladesh from top brands at sensible prices in Bangladesh.
Subcategories
Reference: RBD-0555
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 30A Sensitivity: 100mV/A
Reference: RBD-0169
Flex length: 5.6 cm. Total Length: 2.2″ (7 cm). Life Cycle : >1 million. Height : 0.43mm (0.017″), Resistance Variation: 30K-70K Ohms ±30%. Power Rating: 0.5 Watts.
Reference: RBD-0368
Thickness: 0.4mm Trigger Force: 20g, triggered (default resistance<200kΩ) Pressure Measuring Range: 20g~6kg Static Pressure & Dynamic Pressure Measurement (within the frequency of 10Hz) Initial Resistance: >10MΩ Activation Time: <0.01S Operating Temperature: -40°C~+85°C Lifespan: >1million times Hysteresis: +10%,(RF+ -RF-)/FR+,1000g...
Reference: RBD-0562
Input Voltage: DC3.6V-6V Input Current: 2A-5A Output Voltage: DC 400KV (Please pay attention to safety when used) Input Line Length: about 100mm (red is positive) Output Line Length: about 160mm
Reference: RBD-0687
Operating Voltage: 1.71V to 3.6V – would typically be operated from 3.3V. Operating Temperature: -40 to +85 deg. Celsius (full accuracy between 0 and +65 deg. C). Peak current: 1.12mA. RoboticsBD Operating Pressure: 300 hPa to 1100 hPa. Accuracy between 700 to 900hPa and 25 to 40 deg. C: ±0.12hPa and ±1.0m.
Reference: RBD-1972
Brand: DFRobot
Brand Gravity Analog AC Current Sensor 20A AC Current Signal Conversion Module Open Type AC Transformer Probe Included Non-contact Measurement
Reference: RBD-2346
HW-671 WCS1800 Hall Current Sensor Module with over-current protection Current detection range: DC ±35A, AC 25A High-resolution current detection: 60mV/A Adjustable overcurrent threshold with a resolution of 1.5A Analog and TTL signal outputs for microcontroller integration Compact design with mounting holes for easy installation
Reference: RBD-0417
Easily customizable to a wide range of sizes Cost-effective Ultra-thin; 0.45 mm Robust; up to 10 million actuations Simple and easy to Integrate. RoboticsBD
Reference: RBD-0564
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%
Reference: RBD-1376
SensorModule : MPXV7002DP Measurement Range: 1psi, 100m/s (223mph/360kmh). Resolution: 0.84Pa. Data: Delivered at 14 bits from a 24 bit delta-sigma ADC. Low pass filtered Temperature compensated 10° to 60°C
Reference: RBD-0552
Working frequency: quad-band network, 850 / 900 / 1800 / 1900MHz Working voltage: 4.8-9VDC(On-board voltage regulator circuit supply power for A6 module) Working Current: maximum of 2A. RoboticsBD
Reference: RBD-0982
Model: HX710B Data Output Rate:10 SPS / 80SPS Max. Operating Current (mA):1.5 IC Package:16 Pin SOP
Reference: RBD-1173
Input Current : 100A Frequency: 50HZ-150KHZ Opening Size: 13 x 13mm/ 0.5″ x 0.5″(L*W) Output Plug 3.5mm Dielectric Strength 6000V AC/1min Meet UL94-V0 flame retardant properties
Reference: RBD-0700
Operating Voltage: 3.3V-5.5V Low Power Consumption High Accuracy Small Size
Reference: RBD-1175
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 20A Sensitivity: 100mV/A
Reference: RBD-1847
Compact Design Country Specific pressure Multiple Displayable Unit Multi-colored, two-part display Alphanumeric display Discontinued by Manufactured 2017
Reference: RBD-1174
Low-noise analog signal path. Device bandwidth is set via the new FILTER pin. 5 µs output rise time in response to step input current. Small footprint, low-profile SOIC8 package. 2.1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8.
Reference: RBD-1848
Compact Design Country Specific pressure Multiple Displayable Unit Multi-colored, two-part display Alphanumeric display
Reference: RBD-1018
Dimensions: 75 x 13 x 13 mm (L x W x H) Range: 5 kg Cable Length: 18 cm Fitting ScrewHole Size: M3 Rated output: 1.0 0.1mV / V Nonlinear: 0.05% F.S Hysteresis: 0.0% F.S Repeatability: 0.05% F.S
Reference: RBD-1177
This signal generator can use 4-20mA to generate voltage and control the current in the circuit. Accuracy up to 0.01; Liquid crystal display; Rotary encoder adjustment ; Two connection terminals are non polarity. Output range can be set; 4-20mA (device control) / -21mA (signal debugging) Display mode can be set, it is convenient for you to see the value...